Anyone reading an EPA methane rule for the first time hits a wall of citations - Subpart A, Subpart OOOO, OOOOa, OOOOb - and it is not obvious how they relate. This page is an orientation, not a definition of any single rule. It explains how 40 CFR Part 60 is built, what the general provisions do, why the oil and gas standards carry those long strings of letters, and how to read a citation so you land on the right requirement instead of the wrong one.

Back to Blog

40 CFR 60 Subpart Structure in one line: 40 CFR Part 60 holds the federal New Source Performance Standards. It opens with general provisions that apply to everything, then divides into subparts, each covering one industry or source category. Subparts are lettered, and once the single and double letters were exhausted the naming ran to strings like OOOO, with trailing letters (OOOOa, OOOOb) marking successive versions tied to different applicability dates.

The General Provisions Come First

Part 60 begins with a block of general provisions, historically Subpart A, that apply across the whole part unless a specific subpart says otherwise. These general provisions define the shared machinery: how notifications and reports are handled, how performance tests are conducted, how monitoring and recordkeeping obligations are framed, and what common terms mean. When a source-specific subpart is silent on a procedure, the general provisions usually fill the gap.

This layering matters when you read a rule, because a single industry subpart rarely tells you everything you must do. It tells you the source-specific limits and monitoring, then leans on the general provisions for the procedural backbone. Missing that is a classic first-timer error: reading the methane subpart in isolation, not realizing the reporting mechanics and test methods it relies on live in the general provisions and in referenced appendices.

The general provisions also establish that Part 60 is about new sources. The whole part implements New Source Performance Standards, which reach affected facilities constructed, modified, or reconstructed after a subpart's applicability date. Existing sources are handled through a different mechanism (emission guidelines and state plans), which is the structural reason the methane program needed a separate existing-source track. The distinction between the new-source and existing-source paths is covered in the comparison of OOOOb and OOOOc.

Why the Subparts Carry Long Letter Strings

Each industry or source category in Part 60 gets its own subpart, identified by a letter. Early subparts used single letters, then double letters as the alphabet ran out, and eventually strings of repeated letters. That is all the OOOO in the methane standards is: a subpart identifier that landed far down the sequence, not an acronym. Reading it as a code with hidden meaning is a common misconception; it simply marks a position in the naming order.

The trailing lowercase letters are the part that actually carries meaning for compliance. A base subpart and its successive revisions share the core string and differ by the trailing letter: the original oil and gas methane standard, then a revision, then a further revision, each tied to a different range of construction or modification dates. That is why OOOO, OOOOa, and OOOOb are related but distinct - they are versions of the same source-category standard, each governing sources built or modified within its own applicability window.

The double-O prefix used for existing-source emission guidelines follows a parallel logic in a different part of the regulatory structure. The takeaway for a reader is mechanical but important: the base string tells you the source category, and the trailing letter tells you which vintage of the rule applies, which in turn depends on when your equipment was constructed or modified. Get the trailing letter wrong and you can apply an obsolete or not-yet-effective requirement to a source.

Reading a Citation Without Getting Lost

A full Part 60 citation reads title, part, subpart, section: 40 CFR 60, then the subpart, then a section number within it. To land on the right requirement, resolve it outside in. Confirm you are in Part 60 (New Source Performance Standards, so new or modified sources), identify the subpart to get the source category and rule vintage, then read the section for the specific obligation. Cross-references to the general provisions and to test-method appendices are normal and expected.

The single most useful habit is to check applicability before reading substance. Every subpart has an applicability section that states which affected facilities it covers and the date test. If your source does not meet the applicability, the rest of the subpart is moot; if it does, that section also tells you which trailing-letter version you are in. Confirming applicability first prevents the wasted effort of studying limits that never applied to your equipment.

For an operator, the payoff of understanding this structure is being able to trace any obligation back to its source and forward to what it demands in the field. Once you know which subpart and section govern a piece of equipment, the monitoring and recordkeeping obligations become concrete tags and logs. A platform such as Merobix helps close that last step by trending the parameters a subpart cares about and retaining the history, so a citation on paper corresponds to demonstrable data. The specific methane family that most oil and gas readers arrive looking for is explained in the Quad O overview.

Frequently Asked Questions

What does the OOOO in the EPA rules stand for?

Nothing. OOOO is a subpart identifier within 40 CFR Part 60, produced by the sequential lettering of subparts after the single and double letters were used up. It is not an acronym and has no expanded meaning. The letters after it, as in OOOOa and OOOOb, mark successive revisions of the same oil and gas source-category standard, each tied to a different range of construction or modification dates rather than spelling anything out.

What is the difference between a part, a subpart, and a section in the CFR?

In 40 CFR, the title is 40 (Protection of Environment), the part is a major body of rules such as Part 60 (New Source Performance Standards), the subpart divides a part into source categories or topics identified by letters, and the section is the numbered provision within a subpart that states a specific requirement. A citation like 40 CFR 60 followed by a subpart and section walks you from the general to the specific, which is the order in which you should read it.

Do the Part 60 general provisions apply to every subpart?

Generally yes, unless a specific subpart overrides them. The general provisions at the front of Part 60 set out shared procedures for notifications, reporting, performance testing, monitoring, and recordkeeping, and a source-specific subpart relies on them for the mechanics it does not restate. This is why reading a single subpart in isolation can be misleading: the procedural backbone often lives in the general provisions and in referenced test-method appendices rather than in the subpart itself.

More in Standards, Procedures & Compliance
HART Command Structure  •  Subpart W vs OOOOb  •  21 CFR Part 11  •  e-GGRT Subpart W reporting  •  EPA Subpart W (GHG Reporting)  •  All Standards, Procedures & Compliance →
Free SCADA operator training
Merobix University - 70 video lessons & 261 quiz questions, from first login to compliance reporting. No demo call required.