Professional Services

Allen-Bradley PLC Programming
& Control Panels in Texas

Allen-Bradley and Siemens PLC programming, custom industrial control panel fabrication, and full SCADA integration - engineered, built, and FAT-tested by one Texas team. Tell us what you're building and get a quote back fast.

We Don't Just Monitor -
We Build & Program Too

Beyond the platform, Merobix offers hands-on engineering services. From PLC programming to full panel fabrication - all from one team.

PLC Programming
Siemens PLC Programming
Expert programming for Siemens S7-1200/1500/300/400 using TIA Portal. New builds, retrofits, and troubleshooting.
  • TIA Portal - Ladder, FBD, SCL, STL
  • S7-1200 / S7-1500 program development
  • PROFINET & PROFIBUS configuration
  • HMI integration - KTP & TP panels
  • Legacy migration & remote commissioning
Request Quote →
PLC Programming
Allen-Bradley Programming
Full Rockwell Automation programming using Studio 5000 and RSLogix. ControlLogix, CompactLogix, MicroLogix.
  • Studio 5000 / RSLogix 500 & 5000
  • ControlLogix & CompactLogix development
  • EtherNet/IP network integration
  • PanelView HMI development
  • Legacy MicroLogix migration & support
Request Quote →
Fabrication
Control Panel Fabrication
Custom control panel design and build - from concept to finished cabinet. FAT-tested before it ships to your site.
  • Custom panel design & BOM development
  • Panel assembly, wiring, and labeling
  • PLC, VFD, relay, and I/O integration
  • C1D2-rated enclosure options for hazardous locations
  • Field installation & commissioning available
Request Quote →
PANEL BUILD - BILL OF MATERIALS · WELL #1 CONTROL PANEL FAT-Tested
Siemens S7-1200 CPU 1214C
14 DI / 10 DO / 2 AI
PLC
Allen-Bradley PowerFlex 525
5 HP / 480V / EtherNet/IP
VFD
NEMA 4X Fiberglass Enclosure
24" × 20" × 8" · C1D2 Rated
C1D2
Siemens KTP700 Basic HMI
7" Touch · PROFINET
HMI
Merobix IoT Gateway Module
MQTT · Cloud Push · 4G LTE
IoT
Redundant DCS Controller Module
Redundant CPU · OPC-UA · HART
DCS
SCADA Subscription
Cloud SCADA Subscription
Hosted at scada.merobix.com. No server to provision, no infrastructure to manage. Commissioned on a timeline scoped to your sites.
  • Multi-tenant cloud hosting
  • Automatic updates & backups
  • SSL, MFA, RBAC included
  • Mobile apps for iOS & Android
  • Month-to-month terms available - details in your quote
Request Quote →
SCADA Licensing
On-Premise SCADA Licensing
Run Merobix on your own server. Full data control. Air-gapped capable. Works without internet.
  • Self-hosted on Linux, Windows, Docker
  • Air-gapped & isolated network deployments
  • Hardware locked license option
  • All modules included
  • Annual maintenance & support
Request Quote →
Licensing
Hardware Locked On-Premise
License bound to a specific server fingerprint. Tamper-evident activation for sensitive industrial environments.
  • Bound to MAC, CPU, motherboard signature
  • Offline activation supported
  • Transfer process for hardware refresh
  • Suited for ICS / OT segregated networks
Request Quote →
Onboarding
Setup & Onboarding
We deploy, configure, and train your team. Live on the dashboard in days - not months.
  • Gateway provisioning & install
  • Tag library setup from your I/O list
  • Alarm thresholds & notification routing
  • Live walk-through with your operators
Request Quote →
Integration
Protocol Driver Configuration
drivers across the major protocol families, ready out of the box. We map registers, build tag groups, and validate against your devices.
  • Modbus, EtherNet/IP, OPC UA, DNP3, BACnet
  • Sparkplug B, HART-IP, Profibus, PROFINET
  • Logix native tag browse
  • Multi-driver gateway tuning
Request Quote →
Engineering
Custom Module Development
Need something Merobix doesn't ship with? Our team builds signed modules through the Merobix Exchange.
  • Custom calculation modules
  • Bespoke dashboards & reports
  • Third-party API connectors
  • Signed module verification
Request Quote →
Compliance
Compliance Documentation Packages
IQ/OQ/PQ, validation packets, evidence binders. We supply the auditor-ready paperwork your team would otherwise build from scratch.
  • FDA 21 CFR Part 11 / EU GMP Annex 11
  • NERC CIP evidence packages
  • OSHA PSM & EPA RMP documentation
  • NIST CSF, IEC 62443, ISO 27001 SOA
Request Quote →
Training
Training & Certification
Operator, engineer, and admin tracks. Hands-on with the training simulator. Certificates issued on completion.
  • Operator dashboard & alarm response
  • Engineer tag & driver configuration
  • Admin RBAC, audit, & compliance
  • Custom curriculum on request
Request Quote →
The Complete Package - Hardware + Software
We can program your PLC, build your panel, connect it to Merobix, and have your site live on the dashboard - all from one team.

Everything You Need,
Nothing You Don't

Two ways to run it - fully managed in the Merobix cloud, or licensed on-premise on your own servers. Every tier is sized to your operation, with scope-based pricing or per-protocol surprises. Pricing is custom-quoted on your sites, tags, and team.

Feature Starter Professional Enterprise
Platform Limits
Sites1Up to 5Up to 20
Tags5005,000Unlimited
Users525Unlimited
Devices & gateways550Unlimited
AvailabilityPer service agreementPer service agreementPer service agreement
Core Monitoring - every plan
Live tags & real-time dashboards✓✓✓
Alarms with SMS & email alerts✓✓✓
Process historian & trends✓✓✓
HMI viewer✓✓✓
Mobile apps (iOS & Android)✓✓✓
Reports✓✓✓
System health✓✓✓
Bulk tag import✓✓✓
Shift log✓✓✓
Operations & Maintenance
HMI designer - ✓✓
Work order management - ✓✓
PM scheduler - ✓✓
Spare parts inventory - ✓✓
OEE tracking - ✓✓
Downtime tracking - ✓✓
Lab manager - ✓✓
Inspection rounds (offline-capable) - ✓✓
Operator management & drills - ✓✓
Loop tuning - ✓✓
Permit to work - ✓✓
Calibration management - ✓✓
Cause & effect matrix - ✓✓
SOP manager - ✓✓
Bulk operations & script console - ✓✓
Analytics & AI
Analytics suite - ✓✓
Engineering calculators - ✓✓
AI process assistant - ✓✓
Equipment fingerprinting - - ✓
Root-cause analysis tools - - ✓
Prescriptive intelligence - - ✓
Benchmarking - - ✓
RCM & lifecycle cost analysis - - ✓
Predictive quality - - ✓
Digital twin - - ✓
Compliance & Safety
Management of change (MOC) - - ✓
LDAR - - ✓
Process safety management (PSM) - - ✓
Compliance center - - ✓
GHG calculator - - ✓
NERC CIP - - ✓
Integrations
OData feed & Power BI - ✓✓
Offline sync - ✓✓
HART device configuration - ✓✓
SAP · Maximo · ServiceNow - - ✓
PagerDuty · AWS IoT · Azure IoT · Kafka - - ✓
Tableau - - ✓
Historian federation & gateway network - - ✓
Security & Scale
LDAP & SAML single sign-on - ✓✓
Advanced security (RADIUS, FIDO2, SIEM, zero trust) - - ✓
Hot standby redundancy - - ✓
White label - - ✓
Get a Quote Get a Quote Get a Quote

← Scroll to see all columns →

All plans are custom-quoted based on your operation; your quote lists the full fee schedule.

Fabrication Questions

Yes. We design and build custom industrial control panels, and Class I Division 2 rated enclosure options are available from the hardware manufacturer for wellhead pads, tank batteries, and compressor stations. All panels are FAT-tested before shipping.

Yes - that is the complete package. We program your PLC, build your panel, install the Merobix gateway, configure your tags and alert thresholds, and hand you a fully commissioned site live on the dashboard. One team, start to finish.

Yes. We provide on-site commissioning - our team comes to your location to get everything up and running. We also guide your local electrician through the installation every step of the way.

Ready To Connect
Your Operation?

Join industrial operators who've moved from blind spots to real-time visibility - in days, not months.

Request a Demo →
TLS 1.3 Encrypted
MFA Available on All Accounts
availability per the applicable agreement
Full Audit Log
Role-Based Access Control
C1D2-Rated Hardware Options

Allen-Bradley PLC Programming

Our engineers are trained on Rockwell Automation software including Studio 5000 and RSLogix 5000. We program ControlLogix, CompactLogix, and MicroLogix platforms for oil and gas, water, and manufacturing applications across Texas. New to the platform? Start with our Allen-Bradley PLC programming guide or see how Allen-Bradley PLC service works for Texas operators. When a program is ready for site, the checkout sequence we follow is published as a free seven-phase PLC commissioning checklist.

  • → New PLC program development from scratch
  • → Existing program modification and troubleshooting
  • → Ladder logic, function block, and structured text
  • → PanelView HMI programming
  • → PanelView and remote HMI configuration
  • → Remote programming and on-site commissioning in Texas

Siemens PLC Programming

We program Siemens S7-1200 and S7-1500 PLCs using TIA Portal, covering all IEC 61131-3 languages including LAD, FBD, and STL. Our engineers also handle PROFINET/PROFIBUS networks and Siemens HMI projects. For a deeper look, read our Siemens PLC programming guide.

  • → TIA Portal LAD, FBD, STL, and SCL programming
  • → PROFINET and PROFIBUS network configuration
  • → Siemens Safety Integrated (fail-safe) programming
  • → Siemens HMI design and engineering
  • → SCADA and cloud monitoring integration via OPC-UA
  • → PLC migration from older S5 and S7-300 platforms

Control Panel Fabrication

Merobix fabricates custom industrial control panels for oil and gas, water, and manufacturing applications, with Class I Division 2 rated enclosure options available from the hardware manufacturer. All panels are built, wired, and tested at our Texas facility before delivery. For the shop process itself - from layout drawings through wiring, labeling, and factory acceptance testing - read how our industrial control panels are fabricated. Learn what a UL 508A listing covers in our UL 508A certification guide, or read what UL listing means when buying control panels in Texas.

  • → Custom panel fabrication, wiring, and labeling
  • → Class I Division 2 (C1D2) enclosure options for oil and gas
  • → Custom panel layout design and engineering
  • → PLC, I/O, and VFD installation and wiring
  • → Shop testing and FAT before site delivery
  • → Fast turnaround for Texas operators - panels ship in weeks, not months

SCADA Integration Services

We connect field devices - PLCs, RTUs, sensors, and meters - to Merobix SCADA - cloud or on-premise - or your existing platform. From Modbus configuration to OPC-UA server setup, we handle the full integration from field to dashboard.

  • → Modbus TCP and Modbus RTU device integration
  • → OPC-UA server configuration and tag mapping
  • → MQTT and Sparkplug B broker setup
  • → Cellular and radio communication setup for remote sites
  • → Historian configuration, trending, and reporting
  • → Custom dashboard and alarm configuration

Services FAQ

Yes - Merobix works with oil and gas operators across Texas and neighboring producing regions. We travel to your sites for commissioning and startup, and provide remote support for ongoing program changes and troubleshooting.

We specialize in Allen-Bradley (Rockwell Automation) and Siemens platforms. We also work with a range of other major PLC and control-system manufacturers. Contact us with your specific hardware and we'll confirm compatibility.

Every panel is custom-quoted to your specification - enclosure rating, PLC platform, I/O count, and drawings all drive the price, so we do not publish a standard price range. We provide free quotes based on your specifications - contact us at [email protected] or use the quote form above.

Yes. Most PLC troubleshooting and minor program changes can be done remotely via secure VPN connection to your PLC. For sites already connected to Merobix SCADA, our engineers can view live tags and diagnostics without a site visit, and most issues are resolved remotely - we aim to respond within one business day.