Industries

Monitoring for Every
Industrial Sector

Oil & gas, water, manufacturing, agriculture, power, HVAC, food & beverage, and mining. If it has sensors, Merobix can monitor it.

Built For Every
Industrial Sector

If it has sensors and a communication port, Merobix can monitor it - regardless of brand, protocol, or industry.

Oil & Gas Production
Wellheads, tank batteries, compressor stations. Pressure, flow, level, temperature. C1D2-rated hardware options available. Permian Basin specialists. GHG calc, AGA-3, API 670, production accounting.
CloudOn-Prem
Deep dive →
Pipeline Operations
Compressor stations, gathering systems, custody transfer. TSA SD-02D security, LDAR, compressor monitoring, DNP3 to utility SCADA.
On-Prem Recommended
Water & Wastewater
Pump stations, lift stations, treatment plants. Flow, pH, chlorine, dissolved oxygen, tank levels. EPA reporting, remote site monitoring, utility-grade uptime.
CloudOn-Prem
Manufacturing
Production lines, conveyor systems, CNC machines. OEE tracking, work order management, recipe management ISA-88, SPC. Real-time downtime alerts and shift-level reporting.
On-Prem Recommended
Agriculture
Irrigation systems, grain storage, livestock facilities. Soil moisture, bin temp, pump status, grain dryer monitoring. Cellular gateway for remote field sites.
Power & Energy
Solar farms, substations, generators, wind turbines. Voltage, current, power factor, generation output. DNP3 integration with utility SCADA.
Building & HVAC
Commercial buildings, data centers, cold storage. Temperature, humidity, pressure differential, energy consumption. BACnet/IP and Modbus BMS integration.
Food & Beverage
Processing plants, fermentation, cold chain, bottling lines. Temperature, pressure, flow, batch tracking. Full audit trail for FDA and FSMA compliance.
Mining
Remote equipment, conveyors, slurry pumps, crushers. Vibration, load, bearing temp, pump pressure. Satellite and cellular options for off-grid mine sites.

Purpose-Built for Permian Basin
Oil & Gas Operations

Remote SCADA Monitoring for Texas Oil & Gas

Merobix was designed for upstream oil and gas operations in West Texas - unreliable cell coverage, hazardous classified areas, and constant pressure to keep wellheads, tank batteries, and compressor stations running without rolling a truck.

Connect your existing Modbus RTU wellhead controllers, separator PLCs, and tank level sensors. Everything streams securely to the cloud - readable from your phone, laptop, or truck cab in real time.

We support the Red Lion RAM-9000 and Moxa MGate for hazardous locations - Class I Division 2 ratings available from the hardware manufacturer - used by operators across multiple U.S. basins. No rip-and-replace. Plug in and go live.

Wellhead PressureTank LevelGas Flow RateSeparator PressureModbus RTUModbus TCPRed Lion RAM-9000C1D2 OptionsPermian BasinEagle Ford
<1min
Typical Alert Delivery
SMS and email typically within a minute of any threshold breach
Broad
Protocol Coverage
drivers across the major protocol families - Modbus RTU/TCP, OPC-UA, MQTT, DNP3, EtherNet/IP and more
99.9%
Uptime Target
Enterprise cloud infrastructure with full redundancy
C1D2
Hardware Option
RAM-9000 manufacturer-rated for wellhead pads, tank batteries, compressor stations
∞
Data Retention
Unlimited historical data - query any tag across any time range
No IT
Required
No servers to run on the cloud plan - no VPNs, no firewall changes. Connect gateway, map tags, go live

Oil & Gas SCADA Questions

Yes. Merobix supports Modbus RTU over serial RS-485 - the standard protocol for most wellhead controllers, RTUs, and flow computers used in upstream oil and gas.

Yes. Tank batteries and separator systems are among the most common Merobix deployments. We monitor tank level, wellhead pressure, separator pressure, flowline temperature, and gas flow rate - all with HIHI/HI/LO/LOLO thresholds.

Yes. We recommend the Red Lion RAM-9000 for C1D2 environments - standard at wellhead pads, tank batteries, and compressor stations in the Permian Basin. The RAM-6000 and Raspberry Pi 4 provide lower-cost alternatives for non-hazardous installations.

The Merobix gateway stores data locally when connectivity drops and syncs automatically when restored - no data gaps. For very remote sites, we support satellite uplinks and extended polling intervals.

Ready To Connect
Your Operation?

Join industrial operators who've moved from blind spots to real-time visibility - in days, not months.

Request a Demo →
TLS 1.3 Encrypted
MFA Available on All Accounts
availability per the applicable agreement
Full Audit Log
Role-Based Access Control
C1D2-Rated Hardware Options

Oil & Gas Deep Dive

Cloud SCADA for Upstream Operations

Merobix connects directly to wellhead PLCs, RTUs, and sensors across Permian Basin and East Texas operations, giving operators real-time visibility into every site from a single cloud dashboard - no on-premise servers required.

  • → Wellhead pressure and flow monitoring
  • → Tank level and overfill protection
  • → Separator and treater automation
  • → HIPPS safety system integration
  • → Plunger lift and downhole pump control
  • → Multi-well pad monitoring from one dashboard
Permian Basin East Texas Eagle Ford Haynesville
75%
Fewer Truck Rolls
Remote visibility eliminates most unplanned site visits
24/7
Uptime Monitoring
SMS and email alerts, typically within a minute of a change
<5 min
Alert Response
Know about downtime before your operator calls
500+
Sites Connected
Across Texas, New Mexico, and Oklahoma

Midstream Operations

Merobix monitors compression stations, pipelines, and gathering systems with the same real-time visibility operators rely on upstream. Connect field devices over cellular or radio - no fiber required.

  • → Compressor station monitoring and control
  • → Pipeline pressure and flow measurement
  • → Custody transfer metering integration
  • → Gas quality and BTU monitoring
  • → Leak detection and line integrity alerts
  • → SCADA-ready RTU and PLC integration

Water & Wastewater

Merobix replaces aging legacy SCADA for municipal utilities and industrial water treatment plants with modern monitoring - cloud-hosted or on your own servers - that meets compliance requirements without the maintenance burden.

  • → Pump station monitoring and remote control
  • → Treatment plant SCADA integration
  • → Lift station monitoring with overflow alerts
  • → Chemical dosing control and verification
  • → Compliance data logging and reporting
  • → Multi-site district monitoring from one platform

Manufacturing Monitoring

From discrete manufacturing to continuous process operations, Merobix gives plant managers real-time production data and instant downtime alerts - without replacing existing PLCs or control systems.

  • → Production line monitoring and OEE dashboards
  • → Energy consumption tracking per line
  • → Quality control sensor integration
  • → Downtime event logging and root cause analysis
  • → Predictive maintenance alerts from vibration sensors
  • → Multi-plant visibility from a single cloud dashboard

Industries FAQ

Yes - Merobix is designed for operators of all sizes. Many of our customers are independent producers managing 5–50 wells. There are no minimum site requirements, and our pricing scales with the number of connected sites so small operators pay proportionally less.

Yes. Merobix connects to pump stations, lift stations, and treatment plant PLCs for municipal and industrial water systems. We support Modbus, OPC-UA, and MQTT protocols commonly found in water infrastructure, and provide compliance-ready data logging.

Merobix primarily serves oil and gas (upstream and midstream), water and wastewater, manufacturing, agriculture, and power generation. Our platform supports any industry that uses PLCs, RTUs, or sensors - if your field device speaks Modbus, OPC-UA, or MQTT, we can connect to it.

Most customers are live within 1–2 weeks of project kickoff. For sites with existing PLCs and internet connectivity, connection can be completed in a single day. More complex multi-site deployments with new hardware and cellular modems typically take 2–4 weeks.