● Platform Features
SCADA Software Features
Cloud or On-Premise
Everything you need to monitor, alert, report, and scale - run it in the Merobix cloud, or as on-premise SCADA software on your own servers, air-gapped networks included. Every feature ships in every deployment.
Weighing deployment models? Compare cloud SCADA vs on-premise SCADA, review on-premise SCADA security certifications, or see how SCADA as a service works.
MEROBIX - GATEWAY SETUP
Gateway Configuration - Device Discovery
RAM-9000 Gateway
192.168.1.100 · Port 502 · Modbus TCP
Raspberry Pi 4
10.0.0.22 · MQTT · broker.merobix.com
Moxa MGate 5119
10.0.0.55 · EtherNet/IP · Slot 3
ESP32 Sensor Node
10.0.0.88 · HTTP POST · /api/ingest
✓ gateways detected · protocol drivers ready · Nothing to install on site
Tag Configuration - Oil & Gas Template
TAGLABELUNITHIHIHI
wellhead_psiWellhead Press.PSI9001050
tank_levelTank Level%8595
gas_flowGas Flow RateMSCFD280320
temp_inletInlet Temp°F130150
✓ 4 tags configured · Thresholds active · 8 industry templates available
Live Dashboard - North Field Well #1
Wellhead Pressure
872PSI
Tank Level
67%
Flow Rate
241MSCFD
Temperature
118°F
✓ All systems nominal - Last check 21:17 UTC
▲ Gas Flow Rate nearing HI - SMS sent to J. Harris
Multi-Site Manager - All Sites Overview
North Field Well #1
South Compressor Stn
Midland Tank Battery
Permian Pipeline A
✓ 4 sites · 22 total tags · Add unlimited sites anytime
How It Works
Live In Days,
Not Months
01
Connect Your Hardware
Install a gateway at your site - RAM-9000, Raspberry Pi, Moxa MGate, or any device with a comm port. Supports drivers across the major protocol families.
02
Configure Your Tags
Define what you're monitoring - tag names, units, alarm thresholds, icons. Use an industry template or build your own in minutes.
03
Monitor & Alert
Data flows in real time. View live dashboards, drill into trends, and get SMS or email alerts the instant something goes wrong.
04
Scale Across Sites
Add more sites, more users, more customers from a single control panel. Unlimited growth, one platform.
Platform Features
The Full Platform,
In Every Plan
Real-Time Data Ingestion CloudOn-Prem
Data flows in from any device - drivers across the major protocol families, from Modbus and OPC-UA to MQTT and HTTP POST. Stored in a purpose-built time-series database for millisecond-precision history.
Multi-Channel Alerts CloudOn-Prem
Define HIHI, HI, LO, LOLO thresholds per tag. Fire SMS, email, and push notifications the instant values breach - with suppression to prevent spam.
Historian & Trends CloudOn-Prem
Full time-series storage. Query any tag over any timeframe - 1 hour or 1 year. Custom date ranges with live vs. simulated data indicator.
Multi-Site Map View CloudOn-Prem
See all your sites on a live map. Green means good. Red means someone needs to know. Instant geographic situational awareness.
Role-Based Access CloudOn-Prem
Superadmin, admin, manager, operator roles. MFA enforced. Users only see the sites they're assigned to. Full audit log.
Shift Log & Reports CloudOn-Prem
Operators log notes per shift. Automated daily, weekly, and monthly PDF reports. Compliance documentation built-in.
Configurable Tags CloudOn-Prem
Define any tag for any industry. Set labels, units, icons, colors, and thresholds. Use a template or build your own. No code required.
API Access CloudOn-Prem
Full REST API for integrations. 500+ endpoints. Connect to your ERP, CMMS, or custom dashboards. Webhook support for event-driven architectures.
Mobile Ready CloudOn-Prem
Native mobile app for iOS and Android. Check site status, acknowledge alarms, and review trends from anywhere in the field.
Operations Management
Run The Floor,
End To End
Work Order Management CloudOn-Prem
Full lifecycle CM/PM/EM/CI. Create from alarm automatically. Task checklists and parts tracking. Kanban and table views.
OEE Dashboard ISO 22400-2 CloudOn-Prem
Availability × Performance × Quality. Six Big Losses breakdown. World class benchmark.
Downtime Manager CloudOn-Prem
MTTR, MTBF, Pareto analysis. Root cause required to close.
PM Scheduler On-Prem
Calendar, usage, condition-based. Auto-generate work orders when due. PM compliance reporting.
Spare Parts Inventory On-Prem
Reorder point alerts. Issue parts against work orders.
Lab Manager On-Prem
Sample scheduling and results. Spec limit tracking. Out-of-spec detection.
Operator Certifications On-Prem
H2S, LOTO, Well Control, OSHA 30hr. 30-day expiry alerts. Shift KPI tracking.
Training Simulator On-Prem
5 built-in scenarios. Historical data replay. No real PLC needed.
Inspection Rounds CloudOn-Prem
GPS location verification. QR and NFC check-in. Photo capture per checkpoint. Full offline capability.
Recipe Management ISA-88 On-Prem
Production recipe library. Batch execution tracking. Phase and parameter control.
scada.merobix.com/dashboard

Analytics & AI
Insight Beyond
The Live Value
AI Process Assistant CloudOn-Prem
Claude-powered process chat. Ask about alarms and tags. Root cause suggestions.
Process Fingerprinting CloudOn-Prem
Learn normal operating envelope. Real-time deviation detection. NORMAL/WARNING/ABNORMAL status.
Root Cause Analysis CloudOn-Prem
Fishbone diagram builder. 5-Why analysis. FMEA with RPN calculation. Fault Tree Analysis.
Prescriptive Analytics CloudOn-Prem
Not just predict - prescribe. Recommend optimal actions. 5 built-in rules engine.
Predictive Quality CloudOn-Prem
API gravity from density. Gas BTU from composition. Water cut from capacitance. H2S risk assessment.
Soft Sensors (7 types) CloudOn-Prem
API gravity, viscosity, pump efficiency, gas flow, equipment health, water cut, methane number.
RCM Analysis On-Prem
SAE JA1012 framework. Failure mode identification. Maintenance plan generation.
Life Cycle Cost Analysis On-Prem
Replace vs repair decisions. NPV discounting. Capital planning tool.
Process Benchmarking On-Prem
Compare sites to each other. ISO 22400 industry benchmarks. Gap analysis to world class.
Compliance
10 Frameworks,
One Platform
FDA 21 CFR Part 11 On-Prem
Electronic records and signatures. HMAC audit trail integrity. IQ/OQ/PQ template generator. EU GMP Annex 11 ALCOA+.
NERC CIP (CIP-002 to CIP-014) On-Prem
BES Cyber System asset registry. Evidence package manager. Patch tracking CIP-007 R2.
OSHA PSM (14 Elements) On-Prem
PHA with HAZOP method. 4×4 risk matrix. PSSR workflow. Incident investigation.
EPA GHG (40 CFR Part 98) On-Prem
Combustion, pneumatic, venting, flaring calculations. Annual report EPA e-GGRT format. Subpart W oil and gas.
EPA RMP On-Prem
Applicability checker. Offsite consequence analysis.
CEMS (40 CFR Part 75) On-Prem
Daily calibration records. Data availability tracking. QA/QC procedures.
TSA Pipeline SD-02D On-Prem
Implementation plan generator. 6 security measures checklist. CISA reporting integration.
NIST CSF Full Assessment On-Prem
All 5 functions assessed. Tier ratings per category. Gap analysis report.
IEC 62443-3-3 Assessment On-Prem
FR1 through FR7, SL1 through SL4. Compliance percentage report.
ISO 27001 SOA On-Prem
93 controls documented. 14 domains covered.
scada.merobix.com/historian

Integrations
Plugs Into
Your Stack
SQL Database Connector CloudOn-Prem
SQL Server, MySQL, PostgreSQL, Oracle, SQLite, ODBC. Bidirectional transaction groups. Read SQL into tags. Write tags to SQL tables. Named query library.
Alarm Notification Pipelines CloudOn-Prem
Complex routing and escalation. Push → SMS → Voice chain. Configurable per alarm priority.
Enterprise
Scale Across
Every Site
Enterprise Admin Module On-Prem
Manage multiple gateways. Push configs to all sites. Central health monitoring.
Hot Standby Redundancy On-Prem
Automatic failover. 15 second max failover time. No data loss.
Git Project Versioning On-Prem
Every config change committed. Full history and rollback. Who changed what and when.
Module Plugin System On-Prem
Extend with custom modules. Merobix Exchange marketplace. Signed module verification.
Project Inheritance On-Prem
Enterprise template push. Site-level overrides allowed. Standardize across all sites.
Docker and Kubernetes On-Prem
Container deployment ready. docker-compose included. Raspberry Pi edge support.
Mobile & Field
Built For The
Boots-On-The-Ground
HART Field Device Config CloudOn-Prem
Configure instruments from phone. Read and write device range. Loop current test 4-20mA. Full HART-IP support.
Full Offline Mode CloudOn-Prem
24-hour data cache. Work orders offline. Inspection rounds offline. Smart sync on reconnect.
Protocol Support
broad protocol-driver coverage, Works With
What You Already Have
No rip-and-replace. Merobix connects to your existing PLCs, RTUs, and sensors.
Ready To Connect
Your Operation?
Join industrial operators who've moved from blind spots to real-time visibility - in days, not months.
TLS 1.3 Encrypted
MFA Available on All Accounts
availability per the applicable agreement
Full Audit Log
Role-Based Access Control
C1D2-Rated Hardware Options