Engineering Resources

Engineering Resources

Merobix Engineering •

Working reference material for people who commission, maintain, and monitor industrial control systems. Everything here is free to read, print, and share - no form, no email gate. Each resource stands on its own and cites the primary standards it draws from. For guided reading orders, see the learning paths at Automation University, or browse the video library.

These references pair naturally with the longer guides on the blog. The commissioning checklist, for example, picks up where the panel shop leaves off - the wiring, labeling, and factory acceptance testing described in our guide to industrial control panel fabrication all happen before the first field checkout item is ticked.

Calculators

Interactive engineering calculators that run entirely in your browser: enter your numbers and read the result, with the formula and a worked example shown on every page. Nothing is stored or sent anywhere. Each result is an engineering estimate to verify against manufacturer data and site measurements.

Calculator

4-20 mA Scaling Calculator

Convert between a 4-20 mA loop current and its process value in either direction, with percent of span, from the LRV and URV of a scaled instrument.

Open the calculator →
Calculator

Loop Voltage Headroom Calculator

Check whether a 4-20 mA loop has enough supply voltage for the transmitter after wire, sense, and barrier drops at worst-case current.

Open the calculator →
Calculator

Pt100 Resistance-Temperature Calculator

Convert between Pt100 RTD resistance and temperature using the IEC 60751 coefficients, over the sensor's rated range, in both directions.

Open the calculator →
Calculator

Cable Voltage Drop Calculator

Estimate the round-trip voltage drop on a copper cable run from wire gauge, length, and current, using per-1000-ft resistance at 20 C.

Open the calculator →
Calculator

Horizontal Tank Volume Calculator

Turn a measured level into a liquid volume for a horizontal cylindrical tank, with gallons, barrels, and percent full for the cylindrical body.

Open the calculator →
Calculator

Vertical Tank Volume Calculator

Compute the volume in a vertical cylindrical tank from level, plus a 10-row level-to-volume table for the tank dimensions you enter.

Open the calculator →
Calculator

Engineering Unit Converter

Convert the mixed process units on datasheets and screens: pressure, temperature, volume, flow, and power, with every factor shown.

Open the converter →
Calculator

Orifice Beta Ratio Calculator

Compute the orifice plate beta ratio and velocity-of-approach factor from bore and pipe diameter, and flag beta outside common practice.

Open the calculator →
Calculator

Battery Autonomy Calculator

Estimate how long a battery bank runs a remote load from amp-hours, voltage, depth of discharge, and load, in hours and days.

Open the calculator →
Calculator

Solar Array Sizing Estimator

Estimate the solar array wattage an off-grid site needs from daily load, your local peak sun hours, and a system derate factor.

Open the estimator →
Calculator

HART Loop Resistance Calculator

Sum the series resistance in a HART loop and compare it against the common 230 to 1100 ohm HART communication window.

Open the calculator →
Calculator

Telemetry Data Usage Estimator

Estimate monthly cellular data for a telemetry site from tag count, bytes per sample, polling interval, and protocol overhead.

Open the estimator →

How These Resources Are Maintained

These pages are written and maintained by the Merobix engineering team in an organization voice. They describe common industry practice, not the requirements of any specific site, standard, or regulator - always defer to your own site procedures and to the primary sources cited on each page. Where a value is genuinely site-specific, the resource says so instead of inventing a number.

If you spot a technical error, we want to know. Report it through our corrections page and we will review it against the primary sources.

Sources & Standards

The organizations and reference documents cited most often across these resources: