How to Spot a Hole in Tubing From Pressure Trends

Merobix Engineering • • 7 min read

A hole in the production tubing is a failure that quietly kills a well's performance and can be hard to distinguish from a downhole pump problem, but the casing and tubing pressure trends often carry its signature. A tubing leak lets casing and tubing communicate, and that communication shows up in the pressures. This page is an interpretation guide for spotting a hole in tubing from pressure trends, and for telling it apart from loading and pump problems, so you can direct the right intervention rather than pulling the wrong equipment.

Back to Blog

Spot a Tubing Leak in one line: To spot a hole in tubing from pressure trends, look for casing and tubing pressures that begin to communicate - moving together or converging when they should be independent - and for a loss of lift performance that a leak would cause, such as a rod pump that cannot build the expected fluid load or a well that will not stay unloaded. The signature is casing and tubing pressure tracking each other abnormally. Distinguish it from simple loading or a pump fault by whether the two pressures are communicating.

Read the Casing-Tubing Communication Signature

A hole in the tubing creates a path between the tubing and the casing annulus, so the defining signature is the two pressures beginning to communicate when they should be independent. On a healthy well the casing and tubing pressures move for their own reasons; when a tubing leak develops, changes in one increasingly show up in the other, and the pressures may converge toward each other. Watching for this abnormal coupling of casing and tubing pressure is the primary way to catch a tubing leak from the trends.

The leak also degrades lift because fluid the lift is trying to move escapes back into the annulus through the hole. On a rod-pumped well this can show as a pump that cannot build the fluid load it should, because the fluid it lifts leaks back down; the dynamometer card may look like the pump is underperforming even though the pump itself is sound. Recognizing that a lift performance loss with casing-tubing communication points to tubing rather than the pump is what prevents pulling a good pump.

Read the trends over time, because a tubing leak usually develops and worsens rather than appearing instantly. A gradually growing communication between the pressures, or a slowly worsening lift performance with the pressures increasingly coupled, is the developing-leak pattern. Catching it early from the trend, against the well's normal production tubing behavior, lets you plan an intervention before the leak fully disables the well.

Distinguish a Leak From Loading and Pump Problems

A tubing leak, a well loading up, and a downhole pump problem can all show as lost production, so the pressures are how you tell them apart. The distinguishing feature of a leak is the abnormal communication between casing and tubing pressure. Loading up shows as casing pressure rising and tubing falling without them converging through a leak path; a pump problem shows in the pump's own signals - the dynamometer card or the ESP's differential - often without the casing-tubing coupling a leak causes.

Use the pump diagnostics alongside the pressures to separate a leak from a genuine pump fault. If the pump's own signals say it is working - a rod pump building load, an ESP developing differential - but production is still lost and the pressures are communicating, the fluid is leaking away rather than the pump failing. If the pump signals themselves show a fault, the problem may be the pump. Reading the pump diagnostics and the pressures together resolves which it is, and the dynamometer card is central to that for rod pumps.

Consider that problems can coexist and confirm before acting. A leak can develop alongside a declining well, so the pressures may show both a growing communication and a loading pattern. The pressure trends narrow the diagnosis and point to a likely tubing leak, but confirming it - and locating the hole - is a well-intervention matter for qualified personnel using proper diagnostic methods. The trend tells you where to look; the intervention confirms and fixes it.

Confirm and Direct the Intervention

When the pressure trends point to a tubing leak, the value of the diagnosis is directing the right intervention. A suspected tubing leak calls for well-intervention diagnostics to confirm the leak and find its depth before the tubing is pulled or repaired, which is qualified-personnel work following site and well-integrity procedures. The pressure-trend diagnosis is what gets the right people looking at tubing rather than chasing the pump, saving a wasted pump job.

Treat a developing tubing leak with attention to well integrity. Communication between tubing and casing can have integrity and safety implications beyond lost production, so a suspected leak is not only a production issue. Handling it - the diagnosis, the decision, and the repair - belongs to qualified personnel operating under the site's well-integrity management, and the concept of pressure between annuli connects to broader sustained casing pressure concerns.

After a repair, use the same pressures to confirm the fix. Once the tubing is repaired or replaced, the casing and tubing pressures should return to their normal independent behavior and the lift should recover its performance, both visible against the pre-leak baseline. Watching the abnormal communication disappear and the lift performance return on the trend confirms the intervention landed on the real problem, closing the loop that the pressure diagnosis opened.

Common Mistakes

The most common mistake is reading lost production and lost fluid load as a pump problem and pulling the pump, when a tubing leak lets the lifted fluid escape back to the annulus. Check whether casing and tubing pressures are communicating before blaming the pump.

The second is missing the leak signature because it develops slowly; the abnormal casing-tubing coupling grows over time, so a trend is needed to catch it, not a spot check. The third is treating a suspected tubing leak as purely a production issue, when casing-tubing communication has well-integrity implications that qualified personnel must handle under the site's integrity procedures.

Frequently Asked Questions

How does a tubing leak show up in pressure trends?

A hole in the tubing creates a path between the tubing and the casing annulus, so the two pressures begin to communicate when they should be independent - changes in one increasingly show up in the other, and the pressures may converge. Alongside this, lift performance is lost because the fluid being lifted leaks back into the annulus, so a rod pump may fail to build its expected fluid load even though the pump is sound. The abnormal casing-tubing coupling is the key signature.

How do I tell a tubing leak from a pump problem?

Read the pressures and the pump diagnostics together. A tubing leak shows abnormal communication between casing and tubing pressure, and the pump's own signals may say it is working - a rod pump building load, an ESP developing differential - even though production is lost, because the fluid is leaking away. A genuine pump fault shows in the pump's signals themselves, usually without the casing-tubing coupling. If the pump looks healthy but production is lost and the pressures are communicating, suspect the tubing.

What should I do if I suspect a hole in tubing?

Use the pressure-trend diagnosis to direct the right people to look at the tubing rather than the pump, then have qualified personnel confirm the leak and locate its depth with proper well-intervention diagnostics before pulling or repairing tubing. A tubing leak has well-integrity implications beyond lost production, so it must be handled under the site's well-integrity procedures. After repair, confirm the fix by watching the pressures return to normal independent behavior and the lift performance recover.