Tank Level Monitoring Software
Tank level is one of the most-monitored measurements in the field - for production, for haul scheduling, for overflow prevention, and for chemical and water tanks. Whatever the tank holds, knowing its level remotely and continuously, with alerts at the limits, replaces manual gauging and prevents the two expensive failures: running over and running dry.
Tank level monitoring software reads continuous level from radar, ultrasonic, or float sensors on any tank and streams it to a cloud dashboard, with high- and low-level alarms - so oil, water, and chemical tanks are watched remotely, hauls are scheduled from data, and overflows are prevented.
How Tank Levels Are Measured and Read
Continuous level comes from a sensor - guided-wave or non-contact radar, ultrasonic, hydrostatic pressure, or a float - wired into an RTU or PLC as an analog signal, which a SCADA platform reads. Merobix reads those digitized level tags over Modbus or DNP3 from a cellular gateway, so a tank's level appears live on a dashboard whether the tank is at a battery, an SWD, or a chemical skid. See how transmitters work for the sensor side.
Preventing Overflows and Dry-Outs
High-level alarms prevent overflows and spills; low-level alarms prevent running a tank or a chemical injection dry, which can mean lost treatment or a starved pump. Delivered typically within a minute with escalation, those alerts give time to act. And a continuous level trend in the historian turns haul scheduling and chemical reordering into data-driven decisions instead of guesswork.
What You Get With Merobix
- Alarms that reach a person. SMS and email typically within a minute of a value crossing a threshold, with on-call escalation - included on every plan.
- Cellular edge, no server room. A gateway reads your devices and connects outbound to the cloud - no fixed IP, no VPN, no on-premise SCADA server.
- A built-in historian. Every reading is retained for trends, production reporting, and compliance records, queryable from any browser.
- One team for the whole stack. The same Texas team runs your SCADA and, if needed, programs your PLCs and builds your control panels.
Frequently Asked Questions
What sensors does tank level monitoring use?
Continuous level sensors - guided-wave or non-contact radar, ultrasonic, hydrostatic pressure, or float - wired into an RTU or PLC. A cloud SCADA reads the digitized level over Modbus or DNP3. Merobix reads these over a cellular gateway.
Can I monitor oil, water, and chemical tanks together?
Yes. Any tank with a level sensor feeding an RTU or PLC can be monitored - production, water/SWD, and chemical tanks all appear on one cloud dashboard.
Does tank level monitoring prevent overflows?
Yes. A high-level threshold triggers an alarm with escalation, giving time to divert or dispatch before an overflow. Low-level alarms similarly prevent running a tank or chemical injection dry.
Can I schedule hauls from level data?
Yes. A continuous level trend in the historian shows fill rates, so hauls and chemical reorders are scheduled from data rather than guesswork or fixed rounds.
Sources and verification
This page references the protocol specifications published by the organizations below. Editions, product capabilities, and documentation change over time - confirm current requirements and specifications directly with the source.
- Modbus Application Protocol Specification - Modbus Organization
- Overview of DNP3 (IEEE Std 1815) - DNP Users Group
Merobix is not affiliated with, endorsed by, or sponsored by these organizations; their names are used only to identify the standards and products discussed.
Automation services
Need help turning this into a working system?
Merobix integrates SCADA, programs Allen-Bradley and Siemens PLCs, and designs and fabricates industrial control panels.
Meeting requests are reviewed before confirmation.