Automation Glossary • Hydraulic Fracturing (Frac)

What Is Hydraulic Fracturing (Frac)?

Merobix Engineering • • 4 min read

Hydraulic fracturing - commonly called fracking or a frac - is the stimulation technique that made shale oil and gas economic. By pumping fluid into a well at pressure high enough to crack the rock, then propping those cracks open, it creates flow paths that tight reservoirs would never provide on their own. This guide explains what hydraulic fracturing is, how proppant keeps fractures open, and how a modern staged frac is executed.

Back to Blog

Hydraulic Fracturing (Frac) in one line: Hydraulic fracturing is a well-stimulation method that pumps fluid into a reservoir at pressure high enough to crack the rock, then carries in proppant - typically sand - to hold those fractures open. The propped fractures give oil and gas high-conductivity pathways to flow into the wellbore, unlocking low-permeability formations like shale.

How a Frac Creates and Props Fractures

The rock in a tight formation has permeability so low that fluids can barely move through it. Hydraulic fracturing overcomes this by pumping fracturing fluid into the formation faster than the rock can accept it, raising pressure until the rock parts along fractures. Once the rock is cracked, proppant suspended in the fluid - sand or engineered ceramic grains - is carried into the fractures.

When pumping stops and pressure falls, the proppant remains wedged in the fractures, holding them open against the overburden stress that would otherwise slam them shut. Those propped fractures are far more conductive than the surrounding rock, so hydrocarbons flow through them to the perforations and up the well. The fluid is a mostly water-based mix with proppant and small amounts of additives that control viscosity, friction, and scale.

Staged Fracturing of a Horizontal Well

A modern shale well has a horizontal lateral thousands of feet long, and it is not fractured all at once. Instead the lateral is treated in sequential stages, most commonly with the plug-and-perf method: an isolation plug seals off the already-treated section, a cluster of perforations is shot, and that stage is fractured. The plug is then drilled out or a sliding sleeve is shifted, and the process repeats up the lateral - often dozens of stages per well.

During each stage, large volumes of water, proppant, and additives are pumped by an array of high-pressure pumps at surface. The job is monitored in real time on treating pressure, pump rate, and proppant concentration, and the pressure response shows whether the rock is breaking down and taking the treatment as designed.

Fracturing Data and Monitoring

A frac is a short, intensive, service-company operation run from its own data van, not a permanent facility, so the treatment itself is monitored by dedicated frac control systems rather than a production SCADA platform. Treating pressure, slurry rate, and proppant concentration are logged there for the engineers steering the job. After the well is fractured, flowed back, and put on production, its ongoing behavior is exactly what a cloud SCADA such as Merobix tracks. Merobix reads wellhead tubing and casing pressure and flow tags from the wellsite RTU or flow computer over Modbus or DNP3, letting operators watch how each newly fractured well cleans up and produces over the weeks that follow.

Frequently Asked Questions

What is hydraulic fracturing?

Hydraulic fracturing is a stimulation method that pumps fluid into a reservoir at high pressure to crack the rock, then carries in proppant - usually sand - to hold the fractures open. The propped fractures create high-conductivity pathways for oil and gas to flow into the well, making low-permeability rock like shale productive.

What is proppant and why is it needed?

Proppant is the granular material - typically sand or ceramic - suspended in fracturing fluid and carried into the fractures. When pumping stops and pressure drops, the proppant stays wedged in the cracks, holding them open against the rock stress that would otherwise close them. Without proppant the fractures would seal shut and the stimulation would be lost.

What is plug-and-perf fracturing?

Plug-and-perf is the standard way to fracture a horizontal well in stages. An isolation plug seals off the treated section, a cluster of perforations is shot, and that stage is fractured. The plug is then drilled out and the process repeats up the lateral, letting a long horizontal well be stimulated stage by stage, often across dozens of stages.

Sources and verification

This page references the protocol specifications published by the organizations below. Editions, product capabilities, and documentation change over time - confirm current requirements and specifications directly with the source.

Merobix is not affiliated with, endorsed by, or sponsored by these organizations; their names are used only to identify the standards and products discussed.

More in Oil & Gas Operations
Acid Fracturing  •  Hydraulic Jet Pump  •  Frac Hit  •  Frac Pack  •  Frac Plug  •  All Oil & Gas Operations →
Free SCADA operator training
Merobix University - 70 video lessons & 261 quiz questions, from first login to compliance reporting. No demo call required.
Start free →