Automation Glossary • Gas Capture Percentage (Flaring)

What Is Gas Capture Percentage?

Merobix Engineering • • 6 min read

When associated gas is produced along with oil, it either goes to a pipeline and market or it is burned in a flare, and regulators increasingly want to know what fraction went to good use. Gas capture percentage is the number that expresses that split, comparing the gas an operator captured against the total gas produced. This guide explains what gas capture percentage means and how state regulators use it to limit routine flaring, and shows how metered flare, vent, and sales volumes are reconciled to compute and report the capture ratio.

Back to Blog

Gas Capture Percentage (Flaring) in one line: Gas capture percentage is the share of produced gas that an operator captures and puts to beneficial use, such as sending it to sales, fuel, or reinjection, rather than flaring or venting it. It is calculated as captured volume divided by total gas produced, and state regulators use required minimum capture percentages to limit routine flaring, either statewide or per operator. Computing it accurately depends on metering the gas that is captured, flared, and vented and reconciling those volumes against the total produced.

Capture, Flaring, and Routine Versus Non-Routine

Associated gas comes out of the ground with the oil whether or not there is a way to move it, and an operator has a limited set of destinations for it. It can be captured, meaning sent to a sales pipeline, used on site as fuel, or reinjected, all of which count as beneficial use. Or it can be disposed of, meaning flared, where it is burned, or vented, where it is released unburned. Gas capture percentage measures how much of the produced gas took the first path rather than the second.

Regulators draw an important distinction between routine and non-routine flaring. Non-routine flaring covers safety events, upsets, and situations where flaring is genuinely necessary, such as a well test or an emergency depressurization, and this is broadly accepted. Routine flaring, by contrast, is the habitual burning of gas simply because there is no gathering capacity or no economic incentive to capture it, and it is exactly what capture requirements are meant to squeeze out. The policy goal is to push operators to invest in the infrastructure that turns routinely flared gas into captured gas.

The capture percentage is the yardstick for that goal. By requiring operators to keep captured volume above a minimum share of production, regulators create a direct incentive to build gathering lines, size compression, and time production to available takeaway, because falling below the required capture percentage carries consequences. The number thus translates a broad policy against routine flaring into a concrete, measurable target that an operator either meets or does not.

How State Rules Use the Capture Ratio

State flaring rules commonly set a minimum gas capture percentage that operators must achieve, sometimes as a statewide target that ratchets upward over time and sometimes applied to individual operators or areas. An operator whose capture falls below the required threshold may face limits on its ability to flare, constraints on production, or a requirement to secure specific authorization to continue flaring, so the capture percentage is not just a report but a gate on operations.

Because some flaring is legitimately necessary, the rules typically provide exemptions or allowances that exclude certain volumes from counting against an operator, such as gas flared during well completions, testing, or genuine emergencies. The effect is that the capture calculation has to distinguish between flaring that counts against the target and flaring that is excused, which puts a premium on knowing not just how much gas was flared but why and under what circumstances each volume was burned.

This interplay of a numeric target, exemptions, and consequences means the capture percentage must be defensible, not approximate. An operator reporting its capture has to be able to show the total produced, the captured portion, and the flared and vented portions, and to justify any volumes claimed as exempt. Weak or estimated numbers are a liability when the figure gates whether an operator can keep flaring, so the quality of the underlying volume measurement directly affects an operator's regulatory standing.

Reconciling Volumes with a Monitoring Platform

Computing gas capture percentage is fundamentally a volume reconciliation: total produced gas has to equal the sum of what was captured, flared, and vented, and the capture ratio is the captured slice of that whole. The inputs are all metered quantities, including the gas metered to sales or fuel, the volume through the flare, and any vented volumes, which is precisely the kind of data a cloud SCADA platform such as Merobix reads continuously from flow computers and meters across a site.

Keeping those meters in one place is what makes the reconciliation trustworthy. When sales, flare, and vent volumes are all captured and totaled by the same system, the pieces can be checked against production so that gaps or double counting surface rather than hiding, and the capture percentage falls out of numbers that tie together rather than being assembled from separate, mismatched sources. Because flare metering in particular is easy to under-instrument, having the flare volume measured and stored alongside the sales volume closes a common blind spot.

Continuous accumulation also suits the way capture is reported, since the target is usually assessed over a period rather than an instant. A platform that totals captured, flared, and vented volumes over the reporting window can show the running capture percentage and how it is trending, letting an operator see a shortfall developing while there is still time to divert more gas to sales or reduce flaring. For an operator managing many wells and gathering points, having every relevant meter feed one reconciliation is what makes an accurate, defensible capture figure achievable across the field rather than a manual quarter-end exercise.

Frequently Asked Questions

How is gas capture percentage calculated?

Gas capture percentage is captured volume divided by total gas produced, expressed as a percentage. Captured gas is the portion put to beneficial use, such as sales, on-site fuel, or reinjection, while the rest is flared or vented. Computing it accurately requires metering the captured, flared, and vented volumes and reconciling them against total production so the pieces tie together.

What is the difference between routine and non-routine flaring?

Non-routine flaring covers safety events, upsets, and situations where flaring is genuinely necessary, such as well testing or an emergency, and is broadly accepted. Routine flaring is the habitual burning of gas simply because there is no gathering capacity or no economic incentive to capture it. Gas capture requirements are aimed at eliminating routine flaring by pushing operators to build the infrastructure to capture that gas.

What happens if an operator falls below the required capture percentage?

Depending on the state rule, an operator whose capture falls below the required minimum may face limits on flaring, constraints on production, or a requirement to obtain specific authorization to continue flaring. Because the capture percentage can gate operations, the reported figure must be defensible, backed by metered volumes rather than estimates, including justification for any volumes claimed as exempt.

From Definitions to a Live Dashboard

Merobix reads your field devices into a cloud SCADA - the real thing behind these terms, live in days from any browser.

Request a Free Demo +1 (903) 307-7300
More in Automation Glossary
Storage Vessel Affected Facility  •  Glycol Dehydrator Emissions  •  SWPPP & Stormwater Permit  •  Benzene Waste Operations NESHAP (BWON)  •  The Six Big Losses (OEE)  •  Availability Rate (OEE)  •  All Automation Glossary →
Free SCADA operator training
Merobix University - 70 video lessons & 261 quiz questions, from first login to compliance reporting. No demo call required.
Start free →